Factors related to exchange of disinfection solutions of endoscopic devices
Keywords:
Endoscopy, gastrointestinal. Disinfection. Peracetic acid. Sanitizing products.Abstract
Objective: To identify the factors related to the replacement of disinfection solutions of endoscopes devices. Method: A quantitative study carried out at an endoscopy service in the city of Belo Horizonte, belonging to the Brazilian National Health System, in the period from March 28, 2012 to March 20, 2013. It was carried out a documentary analysis of test records for daily monitoring of chemical disinfection processes in that particular sector. Descriptive statistics were used with frequency distribution and central trend measurements. Results: The following factors related to the replacement of the disinfecting solution of peracetic acid were identified: minimum solution concentration inferior to the required (75%), volume below the ideal amount (15%), presence of deposits and accidental solution spillage, both at 5%. The extra cost estimated on the unnecessary exchanges reached 66.6%. Conclusion: There is a prior need to review the planning and protocols of the service.References
Beilenhoff U, Neumann CS, Rey JF, Biering H, Blum R, Cimbro M, et al. ESGE-ESGENA guideline: cleaning and disinfect in gastrointestinal endoscopy. Endoscopy. 2008;40(11):939-57. 10.1055/s-2008-1077722
C hapman W. The principles of decontamination in gastrointestinal endoscopy. Br J Nurs. 2010;19(11):698-704. PMid: 20622776
Rutala WA, Weber DJ. Reprocessing endoscopes: United States perspective. J Hosp Infect. 2004;56(suppl 2):S27-39.
Chair DBN, Barkun AN , Block KP, Burdick JS, Ginsberg GG, Greenwald DA, et al. Transmission of infection by gastrointestinal endoscopy. Gastrointest Endosc. 2001;54(8):824-8.
Favero MS, Bond WW. Chemical disinfection of medical and surgical materials. In: Block SS, editor. Disinfection, sterilization and preservation. 5th edition. Philadelphia: Lea & Febiger; 2000. p.617-41.
Bond WW, Ott BJ, Franke KA, McCracken JE . Effective use of liquid chemical germicides on medical devices: instrument design problems. In: Block SS, editor. Disinfection, sterilization and preservation. 5th edition. Philadelphia: Lea & Febiger; 2000. p. 1097-106.
C enters for Disease Control and Prevention. Guideline for disinfection and sterilization in health-care facilities. Atlanta: CDC; 2008.
Food and Drug Administration. Cleared sterilants and high level disinfectants with general claims for reusable medical and dental devices. Silver Spring: FDA; 2009.
Brasil. Agência Nacional de Vigilância Sanitária. Resolução RDC nº 14, de 28 de fevereiro de 2007. Aprova o Regulamento Técnico para Produtos Saneantes com Ação Antimicrobiana harmonizado no âmbito do Mercosul através da Resolução GMC nº 50/06, que consta em anexo à presente Resolução. Diário Oficial da União. Brasília, 05 de março de 2007 [acesso em: 2015 Abr 01]. Disponível em: http://portal.anvisa.gov.br/wps/wcm/connect/a450e9004ba03d47b973bbaf8fded4db/RDC+14_2007.pdf?MOD=AJPERES
Brasil. Agência Nacional de Vigilância Sanitária. Resolução RDC nº 34, de 16 de agosto de 2010. Dispõe sobre o Regulamento Técnico para produtos saneantes desinfetantes. Diário Oficial da União, 18 de agosto de 2010 [acesso em: 2015 Abr 01]. Disponível em: http://www.diariodasleis.com.br/busca/exibelink.php?numlink=214998
C arrara D, Shirahige CA, Braga ACPV, Ishioka S, Sakai P, Takeiti MH, et al. A desinfecção de endoscópio com ácido peracético por dez minutos é efetiva? Rev SOBECC. 2013;18(4):38-46.
S ella SRBR, Guizelini BP, Ribeiro H. Validation of peracetic acid as a sporicide for sterilization of working surfaces in biological safety cabinets. J Microbiol Infect Dis. 2012;2(3):96-9.
Rutala WA, Weber DJ. Disinfection and sterilization: an overview. Am J Infec Control. 2013;41(5 suppl):S2-5.
Kovaleva J, Peters FTM, Van Der Mei HC, Degener JE . Transmission of infection by flexible gastrointestinal end and bronchoscopy. Clin Microbiol Rev. 2013;26(2):231-54.
Terci LBD, Rossi VA . Indicadores naturais de pH: usar papel ou solução? Qim Nova. 2002;25(4):684-8.
A lfa MJ , Olson N, Degagné P, Simner PJ. Development and validation of rapid use scope test strips to determine the efficacy of manual cleaning for flexible endoscope channels. Am J Infect Control. 2012;40(9):860-5.
R utala WA, Weber DJ. Sterilization, high-level disinfection, and environmental cleaning. Infect Dis Clin N Am. 2011;25(1):45-76.
Sociedade Brasileira de Enfermagem em Endoscopia Gastrointestinal. Manual de limpeza e desinfecção de aparelhos endoscópicos. Porto Alegre; 2005.
Brasil. Agência Nacional de Vigilância Sanitária. Resolução RDC nº 6, de 10 de março de 2013. Dispõe sobre os requisitos de Boas Práticas de Funcionamento para os serviços de endoscopia com via de acesso ao organismo por orifícios exclusivamente naturais. Diário Oficial da União [acesso em: 2015 Abr 01]. Disponível em: http://bvsms.saude.gov.br/bvs/saudelegis/anvisa/2013/rdc0006_10_03_2013.html
Downloads
Published
How to Cite
Issue
Section
License
By publishing in Revista SOBECC, authors retain the copyright of their article and agree to license their work using a Creative Commons Attribution (CC BY 4.0) International Public License, thus accepting the terms of this license. The CC BY 4.0 license allows others to distribute, remix, adapt, and create from the published article, even for commercial purposes, provided they give due credit to the creators of the work (authors of the article).
The authors grant to Revista SOBECC the right of first publication, to identify itself as the original publisher, and grant to the journal a non-exclusive license to use the work in the following ways: (1) to sell and/or distribute the article in hard copies and/or in electronic format; (2) to distribute parts and/or the entire article in order to promote the journal through the internet and other digital and printed media; (3) to record and reproduce the article in any format, including digital media.
With this license, authors can enter into separate contracts for non-exclusive distribution of the article (e.g., publishing in an institutional repository or as a book chapter), with acknowledgement of authorship and initial publication in Revista SOBECC. Authors are encouraged to publish and distribute their work online after publication in the Revista SOBECC, as this can increase the article's visibility and impact.
In line with the journal's policies, each published article will be assigned a CC BY 4.0 license, which will be visible on the abstract page and in the PDF of each article with the respective link to the license terms.